Sorry, you need to enable JavaScript to visit this website.

Style Variant 28011, Exit or SL, Single-sided, 32 m

  • Viewing distance: 32 meters
  • Single-sided
  • Light source: 8W/T16
  • Protection class 2
  • Degree of protection: IP41
  • Degree of protection: IP54
  • According to DIN4844
  • CGLine Technology
Style Variant 28011, Exit or SL, Single-sided, 32 m

With a viewing distance of 32 m and a pictograms foil set, the Style Variant luminaire is suitable for a wide spectrum of applications. IP54 versions are also optionally available for increased tightness requirements indoors or in canopied outdoor areas. The luminaire is available with a rated operating duration of one or three hours according to application.

Data sheet (907 KB) (PDF)
Tender text (28 KB) (MSWORD)
Download file (317 KB) (JPEG)
Viewing distance 32 m
Luminous flux ΦE/Φnom at end of rated operating time 40%
Housing material Polycarbonate (850 °C glow wire resistant)
Housing colour Light grey, sim. RAL 7035
Weight Rated operating time 1 h: 1.7 kg, Rated operating time 3 h: 1.9 kg
Type of mounting Wall mounting (Exit and SL), ceiling mounting (SL) 
Terminals Mains connection 3 x 2.5 mm² / Bus connection 2 x 1.5 mm²
Connection voltage 230 V AC, 50 Hz
Power consumption mains operation (apparent power/effective power) 16 VA
Permissible ambient temperature Maintained mode -5 °C to +30 °C, Non-maintained mode 0 °C to +35 °C 
Battery Rated operating time 1 h: NiCd 3.6V / 1.5 Ah, Rated operating time 3 h: NiCd 3.6V / 4.0 Ah
Light source 8W/T16, 450 lm
Degree of protection IP41 / IP54
Insulation class ll



  • Self-monitoring self-contained luminaire for stand-alone operation or for connection to the central monitoring device CG Controller CGLine 400 or PC-Interface
  • Test results with fault analysis (lamps, charging and battery circuit) as well as status display (operation, function test, duration test) via 3 coloured LEDs
  • Optional IP54 set for increased sealing requirements for indoor rooms or for canopied outdoor areas
  • Automatic function test (weekly) and duration test (every 3 months)
  • Manual function test or operational duration test via testing buttons
  • Automatic charging monitoring and deep discharge protection with restart inhibit
  • No-load and short-circuit shut-down of the inverter
  • 1 minute delay of normal mode after mains returns (acc. to DIN VDE 0100-718)
  • Blocking function with CG Controller CGLine 400 or PC interface in times of shut-down
  • Luminaires are generally suitable for maintained or non-maintained mode