Sorry, you need to enable JavaScript to visit this website.

Style Industry 48011, Exit or SL, Single-sided, 32 m

  • Viewing distance: 32 meters
  • Single-sided
  • Light source: 8W/T16
  • Protection class 1
  • Degree of protection: IP41
  • Degree of protection: IP54
  • According to DIN4844
  • CGLine Technology
Style Industry 48011, Exit or SL, Single-sided, 32 m

Style Industry with its robust diecast aluminium housing is also highly dependable in challenging ambient conditions. IP54 versions are also optionally available for increased tightness requirements indoors or in canopied outdoor areas. The luminaire is available with a rated operating duration of one or three hours according to application.

Documents
Data sheet (831 KB) (PDF)
Tender text (28 KB) (MSWORD)
Images
Download file (313 KB) (JPEG)

No longer available

Viewing distance 32 m
Luminous flux ΦE/Φnom at end of rated operating time 40%
Housing material Polycarbonate (850 °C glow wire resistant)
Housing colour Light grey, sim. RAL 7035
Weight Rated operating time 1 h IP41:  2.6 kg, Rated operating time 1 h IP54:  3.0 kg, Rated operating time 3 h IP41:  2.8 kg, Rated operating time 3 h IP54:  3.2 kg
Type of mounting Wall or ceiling mounting
Terminals for 2.5 mm²
Connection voltage 230 V AC, 50 Hz
Power consumption mains operation (apparent power/effective power) 16 VA
Permissible ambient temperature Maintained mode -5 °C to +30 °C, Non-maintained mode 0 °C to +35 °C 
Battery Rated operating time 1 h: NiCd 3.6V / 1.5 Ah, Rated operating time 3 h: NiCd 3.6V / 4.0 Ah
Light source 8 W/T16, 450 lm
Degree of protection IP41 / IP54
Insulation class l

 

Features

  • Self-monitoring self-contained luminaire for stand-alone operation or for connection to the central monitoring device CG Controller CGLine 400 or PC-Interface
  • Robust aluminium with powder coating 
  • Test results with fault analysis (lamps, charging and battery circuit) as well as status displays (operation, function test, duration test) via 3 coloured LEDs
  • Automatic function test (weekly) and duration test (every 3 months)
  • Manual function test or operational duration test via testing buttons
  • Automatic charging monitoring and deep discharge protection with restart inhibit
  • No-load and short-circuit shut-down of the inverter
  • 1 minute delay of normal mode after mains returns (acc. to DIN VDE 0100-718)
  • Blocking function with CG-Controller CGLine 400 or PC-Interface in times of shut-down
  • Luminaires are generally suitable for maintained or non-maintained mode