Sorry, you need to enable JavaScript to visit this website.

No longer available: Style Variant 58011, LED, Single-sided, 17 m

  • Viewing distance: 17 meters
  • Single-sided
  • Light source: LED
  • Protection class 2
  • Degree of protection: IP41
  • According to DIN4844
  • CGLine Technology
No longer available: Style Variant 58011, LED, Single-sided, 17 m

With a viewing distance of 17 m and a pictograms foil set, the Style Variant luminaire is suitable for a wide spectrum of applications. LED technology significantly reduces energy consumption. In addition, maintenance effort is reduced to a minimum thanks to the high LED service life of 50,000 hours. One or three hours rated operating duration can be freely specified according to application.

Documents
Data sheet (1012 KB) (PDF)
Tender text (30 KB) (MSWORD)
Images
Download file (185 KB) (JPEG)
Viewing distance 17 m
Luminous flux ΦE/Φnom at end of rated operating time 50 % at 1 h, 20 % at 3 h
Housing material Polycarbonate (850 °C glow wire resistant)
Housing colour Light grey, sim. RAL 7035
Weight 58011 1-3/D LED: 0.75 kg
Type of mounting Wall mounting
Terminals Mains connection 3 x 2.5 mm² / Bus connection 2 x 1.5 mm²
Connection voltage 230 V AC, 50 Hz
Power consumption mains operation (apparent power/effective power) 6.4 VA
Permissible ambient temperature Maintained mode -5 °C to +30 °C, Non-maintained mode 0 °C to +35 °C 
Battery maintenance free and gas tight NiMh 4.8 V / 1.1 Ah
Light source 3 x HighPower LEDs
Degree of protection IP41
Insulation class ll

 

Features

  • Self-monitoring LED self-contained luminaire for stand-alone operation or for connection to the central monitoring device CG Controller CGLine 400 or PC-Interface
  • Selectable operating time 1 h or 3 h
  • Minimum service requirement due to high service life of the LEDs (50000 hours)
  • Brightness selectable in 3 steps
  • Test results with fault analysis (LED, charging and battery circuit) as well as status displays (operation, function test, duration test) via 3 coloured LEDs
  • Automatic function test (weekly) and duration test (every 3 months)
  • Manual function test or operational duration test via testing buttons
  • Automatic charging monitoring and deep discharge protection with restart inhibit
  • 1 minute delay of normal mode after mains returns (acc. to DIN VDE 0100-718)
  • Blocking function with CG-Controller CGLine 400 or PC-Interface in times of shut-down
  • Luminaires are generally suitable for maintained or non-maintained mode