VL 8-1.1, VL 8-2.1

  • Protection class 1
  • Degree of protection: IP20
VL 8-1.1, VL 8-2.1

VL 8-1.1 and VL 8-2.1 CGLine emergency light single supply devices are suitable for fluorescent lamps from 10 - 58 watts. These feature automatic monitoring and can be connected to the central CG-Controller CGLine 400 monitoring facility. The supply devices independently carry out regular tests. The results with fault analyses and status displays are output via a multi-colour LED. Charging technology is equipped with an intelligent control. The integrated capacity counter ensures capacity-related recharging in case of partial discharge, thus increasing battery service life.

Documents
Data sheet (474 KB) (PDF)
Tender text (28 KB) (MSWORD)
Images
Download file (215 KB) (JPEG)

No longer available

Housing material Sheet steel, galvanized
Type of mounting for installation inside luminaires
Weight VL 8-1.1 CGLine  0.80 kg,
VL 8-2.1 CGLine  0.80 kg,
2 x Akku 3.6 V/2.5 Ah 0.50 kg,
2 x Akku 3.6 V/4 Ah 0.86 kg
Batterie maintenance free and gas tight Rated operating time 1 h:  NiCd-Akku 2 x 3.6 V / 2.5 Ah,
Rated operating time 3 h:  NiCd-Akku 2 x 3.6 V / 4.0 Ah
Terminals Mains 2 x 1.5 mm², Data line 2 x 1.5 mm², Luminaire/ECG connection 10 x 1.5 mm²
Connection voltage 230 V AC, 50 Hz
Power consumption mains operation 6 VA
Functional earth necessary
Permissible ambient temperature VL 8-1.1 CGLine -10 °C to +50 °C,
VL 8-2.1 CGLine -10 °C to +50 °C,
Battery  0 °C to +40 °C

 

Features

  • Self-monitoring single power supply for stand-alone operation or for connection to the central  monitoring device CG Controller CGLine 400 or PC-Interface
  • Test button with integrated 3-coloured LED indicator
  • Test results with fault analysis (lamps, charging and battery circuit) as well as status displays  (operation, function test, duration test) via multi colour LEDs
  • Automatic function test (weekly) and duration test (every 3 months)
  • Deep discharge protection with restart inhibit
  • Automatic cut off in case of failures within the lamp circuit
  • Intelligent charge: integrated capacity control for optimized recharge in case of partial discharge
  • Manual function test or duration test with test button
  • Blocking function via CG-Controller CGLine 400 in idle operating times
  • 1 minute delay of normal mode after mains returns (acc. to DIN VDE 0100-718)
  • Luminaires are generally suitable for maintained or non-maintained mode
  • Maintained mode only in connection with additional conventional ballast or electronic ballast
  • The switchover between mains and battery operation is carried out via a 5-pole switchover unit
  • Soft lamp preheat operation